Autotrol 255 valve installation


















For these procedures, you can use the dow. In the user manual, you can find instructions for setting this Autotrol Logix water softener. First, you need to set two programs: system size and time of the day. Then you must set the day of the week and regen time.

Afterward, adjust calendar override, amount of regenerant used in regeneration, estimate system capacity and adjust default hardness settings. Like other models, this also has 8 regeneration cycles for mineral tank plastic beans. This Autotrol water softener is designed for a large home and commercial applications. This valve is a suitable Autotrol controller.

The water softening system is also salt-based and consisted of a brain tank, mineral tank, and a control valve. The mineral tank has a capacity of 48 grain. The whole construction is delivered complete with bypass, tube adapters, and brine tank.

The placement of this Autrol valve should be above 20 feet from the drain. The regeneration of the mineral tank has 8 cycles. There are altogether 9 steps of installation explained in the user manual.

Then you should adjust the program system size and adjust the time of the day. The fourth step is to set time of the week and calendar override which is a standard feature on the controllers. Than set regen time which is several days between time-clock regeneration. The seventh step is to set salt amount, eight-step is to estimate the system capacity which is displayed in the total kilograins of hardness removed before regeneration is necessary.

The last step is to adjust default hardness settings. Like the previous model, this water softening system is salt-based and it consisted of a brain tank, mineral tank, and control valve. It also has a controller with the microprocessor which controls the regeneration and automatically starts it in regards to the flow rate of conditioned water through the included meter.

The controller has a special calendar override feature that must be set during the installation process. This Autotrol controller is suitable for Autotrol valve.

In general, you must set the system size, time of the day and time of a week, together with the calendar. Then you must set default time of regeneration regen time and several days between time-clock regeneration regen frequency. Adjust the regeneration amount of salt, estimate the system capacity displayed in total kilograins of hardness removed before the need to regenerate and adjust defaulted hardness settings.

Regeneration has manual and advanced settings and 8 cycles. The operation of this control valve can be adjusted between three modes: high capacity, standard efficiency and high efficiency low salt consumption. The product is included bypass. The system has grains capacity and non-volatile memory to preserve programmed settings for up to 99 years. These models mentioned on the list are only a smaller part of models offered by this brand. So, for example, you can also buy Autotrol series water conditioner control system, Autotrol tc model, Autotrol osmonics water softener i model, Autotrol model, Logix water softener, Autotrol model, ge Autotrol water softener and Pentair Autotrol water softener.

The main Autotrol water softener parts are the Autotrol valve and controller, mineral and brain tank, and tubes. These Autotrol parts are made specifically for certain models. So Autotrol controlled is suitable with Autotrol or Autotrol valve. Autotrol Performa valve is suitable for Autotrol i timer parts. You can also find Autotrol brand valves series controls or Autotrol series valve i controls.

Depending on the combination, you must read the user manual and pick the right parts. For more information, read my review on Autotrol replacement parts. There are many Autotrol water softener manuals considering the included type of controller suitable and connected with a certain type of valve.

For example, there are Autotrol i manual, Autotrol Logix control time manual, osmonics Autotrol i manual, etc. There you can find a description of valve and controller, step-by-step installation process, maintaining and operating advice, etc. Apply downward hand pressure on control and pull locking bar out Figure Shut off water supply or put bypass valve s into bypass position. Remove cover Figure14 and with a screwdriver, relieve tank pressure by pushing open valve number 6 at rear Figure Figure 17 Outlet Drain 6.

Using a rocking motion, lift control from the tank adapter Figure If O-rings come off with the control put them back into tank adapter sockets. Lubricate O-rings with silicone lubricant. Inlet Figure 14 Figure 15 4. Remove screw in locking bar Figure Figure 18 7. To replace control module, reverse above procedure. Figure 16 10 Specifications Shown with optional i-lid cover PN Hydrostatic Test Pressure Compounded for cold water service Brine Refill Control All are sized to flow 4.

Description Qty. Do not overtighten pipe into Noryl piping boss. Dupont de Nemours and Company, Inc. In rare instances, the turbine wheel of the water meter may collect small particles of oxidized iron, eventually preventing the wheel from turning.

The turbine wheel may be serviced as follows Figure 20 : Injector Screen and Injector The injector is the component which creates the vacuum necessary to draw the brine into the water conditioner. Clean the injector and injector screen once a year in order to maintain proper water conditioning. Some locations may require more frequent injector and screen servicing. Refer to Figure 19 and complete the following steps to clean the injector screen and injector.

Shut off the water supply or put bypass valve s into bypass position. Relieve system pressure by opening valve number 6 at rear with a screwdriver Figure Loosen and remove the fasteners that hold the meter adapter to the tank adapter and the fasteners that hold the piping boss or bypass valve to the meter adapter. Unplug the wall mount transformer. Shut off water supply or put bypass valve s into bypass position and remove the rear cover.

Remove the meter adapter, being careful not to misplace any of the O-rings. Using a needle-nose pliers, grasp one of the four vanes of the gland and, pulling straight out, remove the gland from the adapter.

Using a screwdriver, unscrew and remove the injector screen and the injector cap. Carefully remove the turbine wheel from the housing. Using a toothbrush, lightly scrub the iron off the magnet. Iron buildup on the wheel surfaces may be removed by soaking the wheel in a mild sodium hydrosulfite e. Clean screen with a fine brush. Flush with water until clean. Using a needle-nose pliers, pull the injector straight out.

Squirt water into the injector screen recess of the valve body to flush debris out. Clean and flush injector. Lubricate the O-rings on the injector, injector cap, and injector screen with silicone lubricant and reinstall. Carefully reinstall the gland into the adapter, being certain that the shaft of the wheel seats into the bearing of the gland; press the gland all the way in, being sure the wheel rotates freely.

Important: Do not overtighten the plastic cap. Seat the cap lightly into position. Overtightening may cause breakage of the plastic cap that may not be immediately evident. Reinstall the meter adapter, O-rings, piping boss, or bypass valve, tighten all fasteners and reestablish the water supply to the system.

Reinstall cover, reconnect electric power, and reset the time of day. Check for proper water meter operation by opening a downstream faucet and observing the water flow indicator light on the i display. Screen Injector Brine Control Figure 20 Figure 19 18 Troubleshooting Your water conditioning system is designed and manufactured for efficient, low maintenance service.

However, if problems occur, this section provides a list of possible causes and solutions. You can solve some problems yourself, such as low salt in the salt storage tank or a blown household fuse. However, some problems require installer or dealer assistance. Problem 1. Clock does not display time of day. Important: Service procedures that require the water pressure to be removed from the system are marked with a!.

To remove water pressure from the system, put the bypass valve or three-valve bypass into the bypass position and open the backwash drain valve the sixth valve back from the control with a screwdriver.

Restore system water pressure when the service work is complete. Possible Cause Solution a. Transformer cord unplugged. No electric power at outlet. Connect power. Repair outlet or use working outlet. Defective transformer.

Replace transformer. Defective circuit board. Replace timer. Outlet operated by switch. Use outlet not controlled by switch.

Incorrect voltage or frequency Hz. Replace timer with one of correct voltage and frequency Hz. Power outages. Reset clock. Time display continues to advance. Defective time set switch. Time display shows something other than time of day. Electrical interference. Disconnect power to unit. Restore power and reset time of day display.

No water flow display when water is flowing. Bypass valve in bypass. Shift bypass valve to not-in-bypass position. Fully insert probe into meter housing. Clock does not display correct time of day.

Meter probe disconnected or not fully connected to meter housing. Restricted meter turbine rotation due to foreign material in meter! Remove meter housing, free up turbine and flush with clean water.

Turbine should spin freely. If not, replace meter. Defective meter probe. Control regenerates at wrong time of day. Clock set incorrectly. Reset clock to correct time of day. Timer stalled in regeneration cycle. Motor dead. Motor runs backward. Broken gear. Defective switch. Air leak in brine connections. Binding of camshaft. Continuous regeneration. Camshaft does not stop at the end of regeneration. Check all junction points and make appropriate corrections.

Remove foreign object obstruction from valve discs or camshaft. Water pressure greater than 25 psi 1. Install pressure regulator. Broken switch actuator on gear. Control will not regenerate automatically or when button is pressed. Electric cord or transformer unplugged. Defective motor. Binding in gear train. Control will not regenerate automatically but will regenerate when button is pressed. If water flow display is not operative, refer to Item 5.

Same as Item 5. Incorrect hardness and capacity settings. Set to correct values. See Programming section. Run out of soft water between regenerations.

Improper regeneration. Repeat regeneration, making certain that correct salt dosage is used. Fouled softener resin. Incorrect salt setting. Use resin cleaner. See Note 1. Set salt control to proper level. See salt setting chart. Incorrect hardness or capacity settings. Water hardness has increased.

Set hardness to new value. Turbine should spin freely; if not, replace meter. Control will not draw brine. Brine tank overflow. Low water pressure. Make correct setting according to instructions. Restricted drain line. Injector plugged! Remove restriction. Clean injector and screen. Injector defective! Replace injector and cap. Remove foreign matter from disc and check disc for closing by pushing in on stem. Replace if needed. Air check valve prematurely closed.

Put control momentarily into brine refill. Replace or repair air check if needed. Brine valve disc 1 being held open by foreign matter.

Manually operate valve stem to flush away obstruction. Uncontrolled brine refill flow rate. Remove variable salt controller to clean it and the ball. Flush out foreign matter holding disc open by manually operating valve stem. Valve disc 2 not closed during brine draw causing brine refill. Air leak in brine line to air check. Check all connections in brine line for leaks. Refer to instructions. Improper drain control for injector.

Reference Pressure Graphs. Drain control clogged with resin or other debris. Problem System using more or less salt than salt control is set for. Inaccurate setting. Make correct setting. Foreign matter in controller causing incorrect flow rates. Remove variable salt controller and flush out foreign matter. Defective controller. Replace defective part. Intermittent or irregular brine draw.

Defective injector! Set pump to maintain at least 20 psi 1. Replace both injector and injector cap. No conditioned water after regeneration. Unit did not regenerate. No salt in brine tank. Check for power. Add salt to brine tank. Plugged injector! Remove injector and flush it and injector screen.

Put control momentarily into refill to free air check. Refer to Instructions. Air check valve closed prematurely.